Capacitance Range
25uF - 2100uF
Capacitance Tolerance
Standard capacitance tolerance is ± 10%.
(Other tolerances available on request)
Operating Temperature Range
-40°C TO +85°C (+105°C upon special request)
Hot Spot Temperature Calculation: H.S. = Tamb + (I2 x ESR) x Rth.
Failure Rate: 100FIT
Enclosure/ Construction
Aluminum housing with brass terminals, encased in a plastic cover
Voltage Rating
600VDC - 3000VDC
| Parameter | Method | Condition |
|---|---|---|
| Complies with IEC 1072 | ||
| Vibration | 204 | D |
| Immersion | 104 | B |
| Shock | 213 | I |
| Humidity | 106 | - |
| Thermal Shock | 107 | A |
| Life | 108 | F |